Finishing standard
Finishing standard
General rules: the first floor is the basic module - open space. If the client is interested in smaller modules, 50 % of the cost of the separating walls from the other clients is financed from the fit-out budget. The internal walls are financed in 100% from the fit-out budget. Standard Option
Inside finishing
The basic office module-floor space *  
Division on smaller office modules   *
Toilets in the leased areas with the basic equipment (the number of toilet bowls in the compliance with Industrial Safety Rules) *  
Additional private bathroom   *
Kitchen anexxes - separated *  
Kitchen anexxes - built up (furniture, dish-washer)   *
Suspended ceiling system 60x60 *  
Partition walls - plasterboards white painted up to the suspended ceiling, with the carpet pedestals   *
Partition walls - plasterboards white painted up to the ceiling, with the carpet pedestals   *
Glass partition walls without roller blinds   *
Glass partition walls with roller blinds   *
Fitted carpet 400 gr/m square thick *  
Fitted carpet over 400 gr/m square thick   *
Entrance doors of the office areas - glass aluminum made with the aluminum profile *  
Interior doors of the office rooms - complete door leaves filled with chipboard with the wood veneer frames. Flat double wooden frames.   *
Other finishing elements   *
Electrical installation of tele-and-data communication system
Electric panel and meter on each floor *  
Additional meter   *
Lighting of the office rooms for open space - raster with double parable, brightness up to 500 lux. *  
Additional lighting due to the division of the office - additional raster with the wiring   *
Two general sockets 230V 16 A for the separate 10m2 of the office area *  
Additional electric sockets and the changes of the installation resulting from the section of the office   *
IT cabling   *
Electrical outlets in raised floors   *
UPS connection to the separate socket circuits   *
Ventilation, air-conditioning, heating
Installation of mechanical ventilation - air-exchange 20m3/person with/assuming 1 person for 10 sq m (hourly double air-exchange) *  
Cooling appliances based on the remotely controlled heating and cooling system above the drop ceiling in each office (40 sq m) with one regulator *  
Additional remotely controlled heating and cooling system due to the division of the office area with the regulators   *
Additional air-conditioning of server room
  *
Technical and structural parameters
The space above the suspended ceiling up to 120cm depending on the floor
*  
Raised floor   *
Local expansion of ceiling's load bearing - according to the individual solutions   *
Fire-fighting protection and safety devices
Smoke detectors in office rooms (1/60sq m) *  
Additional smoke detectors due to the division of the office   *
Fire-extinguisher and the marking the office area *  
Security access control
Security gates at entrances and identification system in elevators *  
Access control to the leased area *  
Access control inside the leased area   *
Protection of the leased area by the installation of alarm   *
Entry phone installation between two main entrance door on each floor and leaseholder's reception   *


The following description is not an offer in a legal view and is publicised only for the purposes of information. Presented materials have an illustrative character and can not be treated as final realisation projects.